What Can I Do If an AS Policy Fails to Be Enabled?

  • Description: The alarm rule does not exist.

    Possible cause: The alarm rule used in the alarm policy is deleted.

    Handling method: Change the alarm rule used in the alarm policy and enable the AS policy again.

  • Description: The triggering time of the periodic policy falls outside the effective time range of the policy.

    Possible cause: The periodic policy has expired.

    Handling method: Change the start time and end time of the periodic policy and enable the policy again.

  • Description: The triggering time of the scheduled policy must be later than the current time.

    Possible causes: The triggering time of the scheduled policy has expired.

    Handling method: Change the triggering time of the scheduled policy and enable the policy again.

  • Description: A system error has occurred.

    Handling method: Try again later or contact technical support.