ALM-45439 ClickHouse Node Enters the Read-Only Mode
Alarm Description
The system checks the disk capacity of the ClickHouseServer node every 1 minute. This alarm is generated when the system detects that the disk capacity exceeds 90% and the ClickHouseServer node enters the read-only mode.
This alarm is automatically cleared when the system detects that the disk capacity is lower than 90% and the ClickHouseServer node exits the read-only mode.

If the ClickHouseServer node is in read-only mode and you need to log in to the client to clear data, you can manually exit the read-only mode using the following method:
Log in to FusionInsight Manager, choose Cluster > Services > ClickHouse > Configurations > All Configurations, search for profiles.default.readonly, and change its value to 0.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45439 |
Major |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
DiskPath |
Specifies the path of the disk for which the alarm is generated. |
Impact on the System
After the ClickHouseServer node enters the read-only mode, all write, modification, and deletion operations fail.
Possible Causes
The disk usage of the ClickHouse node exceeds 90%.
Handling Procedure
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
- Expand the disk capacity of the node for which the alarm is generated.
- Go to 4 if the expansion fails or the alarm persists after the expansion.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select ClickHouse for the target cluster.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.