Reviewed-by: Pruthi, Vineet <vineet.pruthi@t-systems.com> Co-authored-by: Yang, Tong <yangtong2@huawei.com> Co-committed-by: Yang, Tong <yangtong2@huawei.com>
8.6 KiB
ALM-45438 ClickHouse Disk Usage Exceeds 80%
Alarm Description
The system checks the disk capacity of the ClickHouseServer node every 1 minute. This alarm is generated when the usage of the disk where the ClickHouse data directory or metadata directory resides exceeds 80%.
This alarm is automatically cleared when the usage of the disk where the ClickHouse data directory or metadata directory is located is lower than 80%.
Alarm Attributes
Alarm ID |
Alarm Severity |
Auto Cleared |
---|---|---|
45438 |
Major |
Yes |
Alarm Parameters
Parameter |
Description |
---|---|
Source |
Specifies the cluster or system for which the alarm is generated. |
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
DiskPath |
Specifies the path of the disk for which the alarm is generated. |
Impact on the System
The ClickHouse write operation may fail.
Possible Causes
The disk capacity of the ClickHouseServer node is too small.
Handling Procedure
- Log in to FusionInsight Manager, choose O&M > Alarm > Alarms, and view the role name and the IP address for the hostname in Location.
- Expand the disk capacity of the node for which the alarm is generated.
- Go to 4 if the expansion fails or the alarm persists after the expansion.
Collect fault information.
- On FusionInsight Manager, choose O&M. In the navigation pane on the left, choose Log > Download.
- Expand the Service drop-down list, and select ClickHouse for the target cluster.
- Expand the Hosts drop-down list. In the Select Host dialog box that is displayed, select the abnormal host, and click OK.
- Click the edit icon in the upper right corner, and set Start Date and End Date for log collection to 1 hour ahead of and after the alarm generation time, respectively. Then, click Download.
- Contact O&M personnel and provide the collected logs.
Alarm Clearance
This alarm is automatically cleared after the fault is rectified.
Related Information
None.