How Do I Enable Structured Log Query?
Scenario
To check the status of asynchronous invocation requests, view the records by choosing Configuration > Configure Async Notification on the function details page, as shown in Figure 1.
Prerequisites
You have enabled asynchronous invocation status persistence.
Procedure
- Contact customer service to add your account to the whitelist of this feature.
- On the Configure Async Notification page, click Enable LTS.
- Click Edit next to Asynchronous Notification Policy, and enable Asynchronous Invocation Status Persistence, as shown in Figure 2 and Figure 3.
- Configure structured query on the LTS console.
- On the function details page, view the log group and log stream. Press F12, choose Network, enter filter async-status-log-detail, and obtain the log group ID and log stream ID, as shown in Figure 4.
- On the LTS console, locate the log group and log stream by their IDs.
- On the log stream details page, click the gear icon in the upper right.
- Configure log structuring.
- Click Intelligent Extraction.
- Click
to modify the field definition as follows:
- Change field1 to function_urn and its type to string.
- Change field2 to request_id and its type to string.
- Change field3 to seq_status and its type to long.
- Change field4 to operation_timestamp and its type to long.
- Change field5 to error_code and its type to long.
- Change field6 to error_message and its type to string.
Enable Quick Analysis.
- Click Save.
Parent topic: General FAQs