Reviewed-by: Pristromskaia, Margarita <margarita.pristromskaia@t-systems.com> Co-authored-by: guoyanyan <guoyanyan3@huawei.com> Co-committed-by: guoyanyan <guoyanyan3@huawei.com>
10 KiB
Modifying Attributes of a BMS NIC
Function
This API is used to specify whether to delete a NIC when the BMS is deleted or the NIC is detached.
URI
PUT /v1/{project_id}/baremetalservers/{server_id}/os-interface/{port_id}
Table 1 lists the parameters.
Parameter |
Mandatory |
Description |
---|---|---|
project_id |
Yes |
Specifies the project ID. For details about how to obtain the project ID, see Obtaining a Project ID. |
server_id |
Yes |
Specifies the BMS ID. You can obtain the BMS ID from the BMS console or by calling the Querying BMSs (Native OpenStack API). |
port_id |
Yes |
Specifies the BMS NIC ID. |
Request
- Request parameters
Parameter
Mandatory
Type
Description
interface_attachment
Yes
Object
Specifies the attribute to be modified. For details, see Table 2.
- Example request
{ "interface_attachment" : { "delete_on_termination": false } }
Response
None
Returned Values
Returned Values |
Description |
---|---|
200 |
The request has been successfully processed. |
For details about other returned values, see Status Codes.
Error Codes
See Error Codes.