<a name="dcs-faq-0730058"></a><a name="dcs-faq-0730058"></a>
<h1 class="topictitle1">When Does a Master/Standby Switchover Occur?</h1>
<div id="body1596093777162"><p id="dcs-faq-0730058__en-us_topic_0209664638_p1273026135619">A master/standby switchover may occur in the following scenarios:</p>
<ul id="dcs-faq-0730058__en-us_topic_0209664638_ul13825740165612"><li id="dcs-faq-0730058__en-us_topic_0209664638_li1182614407563">A master/standby switchover operation is initiated on the DCS Console.</li><li id="dcs-faq-0730058__en-us_topic_0209664638_li68263401567">If the master node of a master/standby instance fails, a master/standby switchover will be triggered.<p id="dcs-faq-0730058__en-us_topic_0209664638_p1493444911524"><a name="dcs-faq-0730058__en-us_topic_0209664638_li68263401567"></a><a name="en-us_topic_0209664638_li68263401567"></a>For example, running commands that consume a lot of resources, such as <strong id="dcs-faq-0730058__b61671835105">KEYS</strong> commands, will cause CPU usage to spike and as result triggers a master/standby switchover.</p>
</li><li id="dcs-faq-0730058__en-us_topic_0209664638_li108263402566">If you restart a master/standby instance on the DCS console, a master/standby switchover will be triggered.</li></ul>
<p id="dcs-faq-0730058__en-us_topic_0209664638_p151011145582">After a master/standby switchover occurs, you will receive a notification. Check whether the client services are running properly. If not, check whether the TCP connection is normal and whether it can be re-established after the master/standby switchover to restore the services.</p>