You can configure an alarm threshold to learn the metric health status. After Send Alarm is selected, the system sends an alarm message when the monitored data reaches the alarm threshold. You can view the alarm information in Alarms.
Parameter |
Value |
Description |
---|---|---|
Rule Name |
CPU_MAX (example value) |
Specifies the rule name. |
Reference Date |
2014/11/06 (example) |
Specifies the date on which the reference indicator history is generated. |
Threshold Type |
|
Specifies the maximum or minimum value of a metric. If this parameter is set to Max. Value, the system generates an alarm when the actual value of the metric is greater than the threshold. If this parameter is set to Min. Value, the system generates an alarm when the actual value of the metric is smaller than the threshold. |
Alarm Severity |
|
Alarm Severity |
Time Range |
From 00:00 to 23:59 (example) |
Specifies the period in which the rule takes effect. |
Threshold |
80 (example) |
Specifies the threshold of the rule monitoring metrics. |
Date |
|
Specifies the type of date when the rule takes effect. |
Add Date |
11/06 (example) |
This parameter is valid only when Date is set to Other. You can select multiple dates. |
Send alarm is selected by default. MRS Manager checks whether the value of each monitored metric reaches the threshold. If the number of consecutive check times is equal to the value of Trigger Count, and the threshold is not reached in these checks, the system sends an alarm. The value can be customized. Check Period (s) indicates the interval at which MRS Manager checks monitoring metrics.