If a recovery task fails, the system attempts to automatically roll back. If the rollback fails, data may be lost. If this occurs, an alarm is reported. This alarm is cleared when the recovery task is successfully executed later.
Alarm ID |
Alarm Severity |
Auto Clear |
---|---|---|
12035 |
Critical |
Yes |
Parameter |
Description |
---|---|
ServiceName |
Specifies the service for which the alarm is generated. |
RoleName |
Specifies the role for which the alarm is generated. |
HostName |
Specifies the host for which the alarm is generated. |
TaskName |
Specifies the task name. |
The data may be lost or the data status may be unknown, which may affect services.
The possible cause of this alarm is that the component status does not meet the requirements before the restoration task is executed or an error occurs in a step during the restoration task. The error depends on the task details. You can obtain logs and task details to handle the alarm.
Checking the component status
Collecting fault information
This alarm is automatically cleared after the fault is rectified.