If users need to view alarms and events of a cluster on the unified alarm reporting platform, you can use the Syslog protocol on FusionInsight Manager to report related data to the alarm platform.
If the Syslog protocol is not encrypted, data may be stolen.
The Syslog service is disabled by default. indicates that the service is enabled.
Parameter Area |
Parameter |
Description |
---|---|---|
Syslog Protocol |
Server IP Address Mode |
Specifies the IP address mode of the interconnected server. The value can be IPV4 or IPV6. |
Server IP Address |
Specifies the IP address of the interconnected server. |
|
Server Port |
Specifies the port number for interconnection. |
|
Protocol |
Specifies the protocol type. The options are as follows:
|
|
Severity Level |
Specifies the severity of the reported message. The options are as follows:
|
|
Facility |
Specifies the module where the log is generated. For details about the available values of this parameter, see Table 2. Default value local use 0 (local0) is recommended. |
|
Identifier |
Specifies the product ID. The default value is FusionInsight Manager. The identifier can contain a maximum of 256 characters, including letters, digits, underscores (_), periods (.), hyphens (-), spaces, and the following special characters: | $ { } |
|
Report Message |
Report Format |
Specifies the message format of the alarm report. For details, see the help information on the page. The report format can contain a maximum of 1024 characters, including letters, digits, underscores (_), periods (.), hyphens (-), spaces, and the following special characters: | $ { } NOTE:
For details about each field in the report format, see Table 3. |
Alarm Type |
Specifies the type of the alarm to be reported. |
|
Alarm Severities |
Specifies the level of the alarm to be reported. |
|
Uncleared Alarm Reporting |
Periodic Uncleared Alarm Reporting |
Specifies whether to report uncleared alarms in a specified period. You can toggle on or off the function. The function is toggled off by default. |
Report Interval (min) |
Specifies the interval for periodically reporting uncleared alarms. This parameter is valid only when Periodic Uncleared Alarm Reporting is enabled. The default value is 15, in minutes. The value ranges from 5 to 1440 (one day). |
|
Heartbeat Settings |
Heartbeat Reporting |
Specifies whether to periodically report Syslog heartbeat messages. You can toggle on or off the function. The function is toggled off by default. |
Heartbeat Interval (minutes) |
Specifies the interval for periodically reporting heartbeat messages. This parameter is valid only when Heartbeat Reporting is enabled. The default value is 15, in minutes. The value ranges from 1 to 60. |
|
Heartbeat Packet |
Specifies the heartbeat message to be reported. This parameter is valid when Heartbeat Reporting is toggled on and cannot be left blank. The value can contain a maximum of 256 characters, including digits, letters, underscores (_), vertical bars (|), colons (:), spaces, commas (,), and periods (.). |
After the periodic heartbeat packet function is enabled, packets may be interrupted during automatic recovery of some cluster error tolerance (for example, active/standby OMS switchover). In this case, wait for automatic recovery.
Severity Level |
Facility |
Numeric Code |
---|---|---|
Emergency |
kernel messages |
0 |
Alert |
user-level messages |
1 |
Critical |
mail system |
2 |
Error |
system daemons |
3 |
Warning |
security/authorization messages (note 1) |
4 |
Notice |
messages generated internally by syslog |
5 |
Informational |
line printer subsystem |
6 |
Debug |
network news subsystem |
7 |
- |
UUCP subsystem |
8 |
- |
clock daemon (note 2) |
9 |
- |
security/authorization messages (note 1) |
10 |
- |
FTP daemon |
11 |
- |
NTP subsystem |
12 |
- |
log audit (note 1) |
13 |
- |
log alert (note 1) |
14 |
- |
clock daemon (note 2) |
15 |
- |
local use 0~7 (local0 ~ local7) |
16 to 23 |
Information Field |
Description |
---|---|
dn |
Cluster name |
id |
Alarm ID |
name |
Alam name |
serialNo |
Alarm serial number NOTE:
The serial numbers of the fault alarms and the corresponding clear alarms are the same. |
category |
Alarm type. The options are as follows:
|
occurTime |
Time when the alarm was generated |
clearTime |
Time when this alarm was cleared |
isAutoClear |
Whether an alarm is automatically cleared. The options are as follows:
|
locationInfo |
Location where the alarm was generated |
clearType |
Alarm clearance type. The options are as follows:
|
level |
Severity. The options are as follows:
|
cause |
Alarm cause |
additionalInfo |
Additional information |
object |
Alarm object |